MH5300

Hydrogen Pressure Transducer

  • High Accuracy
  • Compact
  • Variety of Pressure Ports and Electrical Configurations
  • CE Compliant and Weatherproof
  • Safe and reliable integrated structure design
  • The most compatible 316L stainless steel
  • No oil filled, No leakage
  • No welding, Increase overload capacity
  • Up to ±1% Total Error Band
  • Overcome hydrogen permeability and embrittlement
  • Compact Outline
  • -40°C to +125°C Operating Temperature
  • 0°C to +70°C Compensated Temperature
  • PEM Fuel Cells
  • Hydrogen Station,Hydrogen Storage
  • Hydrogen Fueled Vehicles
  • Hydrogen Backup power
  • Hydrogen Test Machine
  • Train brake

PERFORMANCE SPECIFICATIONS

PARAMETERS MIN TYP MAX UNITS NOTES
Accuracy (combined non linearity, hysteresis, and repeatability)

-0.5

±0.25

0.5

%F.S. BFSL @ 25°C
Zero Error

-0.5

±0.5

0.5

%F.S. BFSL @ 25°C
Full Scale Error

-0.5

±0.5

0.5

%F.S. BFSL @ 25°C
Isolation (Body to any Lead) 100     @250VDC

Pressure Cycles

1X107     0~FS Cycles  
Proof Pressure 3X     Rated  
Burst Pressure 5X   20k psi Rated  
Long Term Stability (1 year) -0.25   0.25 %F.S  
Total Error Band -1.5 ±1.0 1.5 %F.S Over compensated temp range
Compensated Temperature 0   70 °C  
Operating Temperature -40   125 °C Except cable 105°C max
Storage Temperature -40   125 °C Except cable 105°C max
Load Resistance (RL) RL > 100k     Ω Voltage Output
Load Resistance (RL) < (Supply Voltage-9V) / 0.02A     Ω Current Output
Current Consumption     10 mA Voltage Output
Rise Time (10% to 90%) <2ms (Voltage Output); <3ms (Current Output); Without Snubber
Pressure Port Material SST316L
Shock 50g, 11msec Half Sine Shock per MIL-STD-202G, Method 213B, Condition A
Vibration ±20g, MIL-STD-810C, Procedure 514.2-2, Curve L